Link to Overview of Prairie View Corporation Link to New Equipment for sale at Bruggink's Inc Used Construction Equipment available at Brugginks Used trailers available at Bruggink's Aerial Equipment Sales and Services at Brugginks Miscellaneous Implements available at Bruggink's Rental equipment available at Bruggink's

Thawzall models and specs:  Choose the machine that's right for you!

Thawzall links

Bruggink Home
Thawzall Home
Thawzall Advantage
Models & Specs
Accessories
Power Blanket™
FAQ and Manuals •


Thawzall™ Units: designed to overcome cold weather obstacles. 

Models featured below:

H150   H150LS  H250  H250SL  XH850

 

To purchase or rent a unit, call us today!
also check out great buys on our
used ground thawing equipment
 
H150 Thawzall
H150 Performance and Specs

Thawzall's patented HeatZone™ technology THAW's faster, CURE's concrete more uniformly and provides dry, flameless HEAT to winter construction jobs. Model H150 is well suited for small to medium size jobs. Use as emergency backup for installed heating system

Input/Output 175,000 / 148,000 BTUs   Circulation Zones 2
       
Ground THAW 1,200 to 2,400 sq ft Circulation Pump single centrifugal
       
Concrete CURE 2,400 sq ft to 6,000 max Hose length 1,200 feet **
       
FROST prevention 2,400 sq ft to 6,000 max Fuel Requirements winter blend diesel or #1 fuel oil
       
HEAT buldings 210,000 cu ft Operator's Manual

** 2 zones x 600 ft

  Diesel Generator -- 3.5 o4 6.5 KWH; liquid cooled

 H150SL Thawzall
H150SL Performance and Specs

EMBED and ABANDON
This special purpose configuration allows the user to evenly and accurately set the return temperature of the Hi\150LS from 70° to 110° F. Uses include: "Embed & Abandon™" HeatZone™ technology whereby a user pours a slab with embedded hydronic tubing to cure the slab and then abandons the tubing within the slab. This technique results in significant manpower savings over traditional CURING methods.

Input/Output 175,000 / 148,000 BTUs   Circulation Zones 2
       
Ground THAW n/a Circulation Pump single centrifugal
       
Concrete CURE 2,400 sq ft Hose length 1,200 feet **
       
FROST prevention 3,600 sq ft to 6,000 max Fuel Requirements winter blend diesel or #1 fuel oil
       
HEAT buldings 210,000 cu ft Operator's Manual

** 2 zones x 600 ft

  Diesel Generator -- 3.5 o4 6.5 KWH; liquid cooled
| return to top |

H250 Thawzall
H250 Performance and Specs

Replaces the proven Model 6A.  Improved capability with patented HeatZone™ fluid distribution technology.  Superior THAW, CURE, HEAT for any job. Delivers a blistering 250,000 BTU of HEAT with unparalleled uniformity through 3000 feet (5 zones of 600 ft) of 5/8" hydronic heat hose. Expandable with accessories.

Input/Output 280,000 / 234,000 BTUs   Circulation Zones 5
       
Ground THAW 3,000 sq ft to 6,000 max Circulation Pump twin
       
Concrete CURE 9,000 sq ft to 27,000 max Hose length 3,000 feet **
       
FROST prevention 9,000 sq ft to 27,000 max Fuel Requirements winter blend diesel or #1 fuel oil
       
HEAT buldings 400,000 cu ft Operator's Manual

** 5 zones x 600 ft

  Diesel Generator -- 6.0 or 6.5 KWH; liquid cooled
| return to top |

H250SL Thawzall
H250SL Performance and Specs

Revolutionize your winter construction projects with innovation. HeatZone™ patented technology enables winter contractors to precisely control concrete CURING temperatures and/or select THAW with a flick of the wrist.  No more complicated (and possibly expensive) guessing games as to what furnace temperature setting will give you the proper CURE temperature.

Input/Output 280,000 / 234,000 BTUs   Circulation Zones 5
       
Ground THAW 3,000 sq ft to 4,500 max Circulation Pump single
       
Concrete CURE 6,000 max Hose length 3,000 feet **
       
FROST prevention 6,000 sq ft to 9,000 max Fuel Requirements winter blend diesel or #1 fuel oil
       
HEAT buldings 400,000 cu ft Operator's Manual

** 5 zones x 600 ft

  Diesel Generator -- 6.0 or 6.5 KWH; liquid cooled
| return to top |

Model: XH850
XH850 Extreme Heat Performance and Specs

A gargantuan reservoir of HEAT energy wrapped up in a conveniently portable package.  Rated at over one million BTU's per hour, the XH850 delivers extreme heat for all winter construction applications.  It features 4 independent closed loop circulation systems giving the user unmatched flexibility to mix and match THAW, CURE, HEAT applications. 

Input/Output 1,083,000 / 900,000 BTUs   Circulation Zones 4
       
Ground THAW 12,000 sq ft to 72,000 max Circulation Pumps 4 centrifugal
       
Concrete CURE 36,000 sq ft to 72,000 max Hose length **
       
FROST prevention 36,000 sq ft to 72,000 max Fuel Requirements Oil, LP or Natural Gas
       
HEAT buldings 1,500,000 cu ft Operator's Manual

** Base XH850 is configured without hose.  Must add accessory hose reel with either 1,000 1" hose for hydronic heater or 3,000 x 5/8" hose for THAW and/or CURE.  Multiple hose reels may be required depending upon application. 